| Name: | LRS-200-12 12V 17A 200W LRS POWER SUPPLY |
|---|---|
| Output Power | 200W |
| Output Voltage | 12V |
| Output AMP | 17A |
| AC Input Voltage range | 90~132VAC/180~264VAC(selected by switch) ,240~373VDC |
| Warranty | Lifetime Warranty |
| Certificate | CE LVD EMC ROHS |
| Protection | OVER LOAD,OVER VOLTAGE |
Product Description



LIFETIME WARRANTY LRS series CCTV switching power supply
200W 12V 17A SMPS LED power supply
| MODEL | LRS-200-5 | LRS-200-12 | LRS-200-24 | |
| OUTPUT | DC VOLTAGE | 5V | 12V | 24V |
| RATED CURRENT | 40A | 17A | 8.8A | |
| CURRENT RANGE | 0-40A | 0~17A | 0~8.8A | |
| RATED POWER | 200W | 204W | 211.2W | |
| RIPPLE & NOISE | 150mVp-p | 150mVp-p | 150mVp-p | |
| DC VOLTAGE ADJ. RANGE | ±10% | ±10% | ±10% | |
| VOLTAGE TOLERANCE | ±3% | ±2% | ±1% | |
| LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
| LOAD REGULATION | ±2% | ±1% | ±0.5% | |
| SETUP, RISE, HOLD TIME | 800ms,50ms,16ms/230VAC(full load) | |||
| INPUT | VOLTAGE RANGE | 90~132VAC/180~264VAC(selected by switch) ,240~373VDC( Withstand 300VAC surge input for 5 second) | ||
| FREQUENCY RANGE | 47~63Hz | |||
| AC CURRENT | 4.0A/115VAC 2.2A/230VAC | |||
| EFFICIENCY | 85% | 87% | 89% | |
| INRUSH CURRENT | Cold start55A/230VAC | |||
| LEAKAGE CURRENT | <2mA/240VAC | |||
| PROTECTION | OVER LOAD | Rated output power110%~140% Start overload protection | ||
| Protection type:hiccup mode,auto-recovery after fault condition is removed | ||||
| OVER VOLTAGE | Rated output power115%~135% Start over voltage protection | |||
| Protection type:cut off the output,auto-recovery after fault condition is removed | ||||
| OVER TEMPERATURE | 100℃±10℃(RTH3 detect beside magnetic core) | |||
| Protection type:cut off the output,auto-recovery after the temperature become normal | ||||
| ENVIRONMENT | WORKING TEMPERATURE | -25℃~+70℃(Please refer to“derating curve”) | ||
| WORKING HUMIDITY | 20%~90%RH Non-condensing | |||
| STORAGE TEMP, HUMIDITY | -40℃~+85℃;10%~95%RH Non-condensing | |||
| WITHSTAND VIBRATION | 10~500Hz,3G 10min./1Cycle,Period for 60min,Each axes | |||
| SAFETY | WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/70%RH | |||
| FIT STANDARD | SAFETY STANDARD | Compliance to UL60950-1,TUV EN60950-1,GB4973 | ||
| EMC STANDARD | Compliance to EN55022(CISPR22)Class B,GB9254 Class B,EN55014,EN61000-3-2,3 | |||
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1 | |||
| OTHERS | DIMENSION | 215*115*30(L*W*H) | ||
| WEIGHT | 0.66kg | |||
| MTBF | ≥320K hrs min. MIL-HDBK-217F(25℃) | |||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||
| 3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||