| Name: | DR-240-48 48V 5A 240W DIN RAIL POWER SUPPLY |
|---|---|
| Output Power | 240W |
| Output Voltage | 48V |
| Output AMP | 5A |
| AC Input Voltage range | 100~240VAC,135~373VDC |
| Warranty | Lifetime Warranty |
| Certificate | CE LVD EMC ROHS |
| Protection | OVER LOAD,OVER VOLTAGE |
Product Description



LIFETIME WARRANTY 48V 5A 240W DIN RAIL power supply 220V ac to 48V dc DR power supply
| Model | DR-240-24 | DR-240-48 | |
| OUTPUT | DC voltage | 24V | 48V |
| Rated output current | 10A | 5A | |
| Output current range | 0-10A | 0-5A | |
| DC power | 240W | 240W | |
| Ripple and noise | 120mVp-p | 150mVp-p | |
| VOLTAGE ADJ. RANGE | 21.6 ~ 26.4V | 43.2 ~ 52.8V | |
| Voltage tolerance | ±1% | ±1% | |
| line regulation | ±1% | ±1% | |
| Load regulation | ±1% | ±1% | |
| Setup,rise time | 800ms,60ms/230VAC 1000MS,30MS/115VAC at full load | ||
| Hold up time | 50ms/230VAC 20ms/115VAC at full load | ||
| INPUT | AC voltage range | 100-240VAC,135~373VDC | |
| Frequency range | 47-63Hz | ||
| Efficiency | 85% | 86% | |
| AC current | 3.5A/115VAC 1.8A/230VAC | ||
| Inrush current | COLD START 30A/115VAC 60A/230VAC | ||
| Leakage current | <3.5mA/240VAC | ||
| PROTECTION | Overload | Above 105% rated output power | |
| Protection type:Hiccup mode,recovers automatically after fault condition is removed | |||
| Over-voltage | 27.6-32.4V | 55.2-64.81V | |
| protection type:Shut down o/p voltage,re-power on torecover | |||
| ENVIRONMENT | Working temp. | -10~+60℃ | |
| Working humidity | 20~90% RH non-condensing | ||
| store temp.,humidity | -20~+85℃,10~95% RH | ||
| Temp. coefficient | ±0.03%/°C (0~50°C ) | ||
| OTHER | Overall dimension | 125.5*125*100 mm | |
| Weight | 1.15Kg | ||
| CERTIFICATE | CE EMC Authenticate | EN55022:2010 EN61000-3-2:2006+AL:2009 EN61000-3-3:2008 | |
| EN55024:2010 EN55015:2006+AL2007+2009 EN61547:2009 | |||
| CE LVD Authenticate | EN61347-1:2008T A1:2001 EN61347-2-13:2006 | ||
| EN60950-1:2006+A11:2009+A1:2010+A12:2001 | |||
| ROHS Authenticate | EPA3050B:1996 EN1122B:2001 EPA3052:1996 EPA3060A:1996 | ||
| EPA7196A:1992 EPA3540C:1996 EPA8270D:2007 IEC62321:2008 | |||